- Manuals
- Brands
- Noritz Manuals
- Water Heater
- N-0751M-OD
- Owner's manual
Tankless gas water heater
Hide thumbs Also See for N-0751M-OD:
- Installation manual (27 pages) ,
- Installation manual (120 pages) ,
- Service manual (96 pages)
-
- Contents
- Table of Contents
- Troubleshooting
- Bookmarks
Table of Contents
-
Important Safety Information
-
Table of Contents
-
Contents
-
General Parts
-
Main Unit
-
Remote Controller
-
-
Initial Operation
-
How to Use
-
Muting the Remote Controller
-
Setting and Using the Water Heater
-
Flow Meter Alarm
-
Adjusting the Maximum Output Temperature
-
-
Preventing Damage from Freezing
-
Regular Maintenance
-
Troubleshooting
-
Follow-Up Service
-
Specifications
Advertisem*nt
Quick Links
- 1 General Parts
- Download this manual
TANKLESS GAS WATER HEATER
Owner's Guide
WARNING
- Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
CERTIFIED
R
Low NOx
Approved by
SCAQMD
SAR8559-2
Rev. 03/08
Model N-0751M-OD
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury, or death.
Thank you for purchasing this Noritz Tankless Gas Water Heater.
Before using, please:
Read this manual completely for operation instructions.
Completely fill out the warranty registration card (included separately) and
mail the detachable portion to Noritz America Corporation.
Keep this manual (and the remainder of the warranty registration card) where it
can be found whenever necessary.
Installation must conform with local codes, or in the absence of local codes,
the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Noritz America reserves the right to discontinue, or change at any time, the
designs and/or specifications of its products without notice.
NORITZ America Corporation
*SAR8559 T*
Table ofContents
Advertisem*nt
Table of Contents
Related Manuals for Noritz N-0751M-OD
-
Water Heater Noritz N-0751M Installation Manual
Tankless gas water heater (120 pages)
-
Water Heater Noritz NR50-OD Service Manual
(96 pages)
-
Water Heater Noritz N-0751M-OD Installation Manual
Tankless gas water heater (27 pages)
-
Water Heater Noritz N-0751M Owner's Manual
Tankless gas water heater (26 pages)
-
Water Heater Noritz N-0931M Installation Manual
Tankless gas water heater (34 pages)
-
Water Heater Noritz N-0751M Owner's Manual
Tankless gas water heater (26 pages)
-
Water Heater Noritz NR98 Series Instructional Manual
Fan replacement and cleaning procedure (4 pages)
-
Water Heater Noritz N-0531S Field Manual
Gas water heater (60 pages)
-
Water Heater Noritz N-0751M-DV Installation Manual
Tankless gas water heater (29 pages)
-
Water Heater Noritz NC199-DVC Owner's Manual
Tankless (28 pages)
-
Water Heater Noritz N-0751M-DVC Installation Manual
Tankless gas water heater (52 pages)
-
Water Heater Noritz N-0751M-DVC Installation Manual
Tankless gas water heater (27 pages)
-
Water Heater Noritz N-0931M Owner's Manual
Tankless gas water heater (26 pages)
-
Water Heater Noritz N-0931M-ASME Installation Manual
Tankless gas water heater (128 pages)
-
Water Heater Noritz N-0842MC Installation Manual
Condensing tankless gas water heater (140 pages)
-
Water Heater Noritz N-084M Owner's Manual
(67 pages)
Summary of Contents for Noritz N-0751M-OD
- Page 1 Installation must conform with local codes, or in the absence of local codes, SCAQMD the National Fuel Gas Code, ANSI Z223.1/NFPA 54. Noritz America reserves the right to discontinue, or change at any time, the designs and/or specifications of its products without notice. NORITZ America Corporation SAR8559-2 Rev.
-
Page 2: Important Safety Information
Important Safety Information-1 To prevent damage to property and injury to the user, the icons shown below will be used to warn of varying levels of danger. Every indication is critical to the safe operation of the water heater and must be understood and observed. Potential dangers from accidents during installation and use are divided into the following four categories. - Page 3 3. Turn off gas and water supply • Do not try to light any valve. appliance. 4. Call the nearest Noritz agent • Do not touch any electrical switch; do not use any phone in your building. Explosion Hazard ;...
- Page 4 Important Safety Information (Continued) Do not place the unit in an indoor en- Do not store or use gasoline or vironment by means of adding walls other flammable vapors and liquids and ceiling (Do not enclose using in the vicinity of this or any other Prohibited Prohibited corrugated sheets, etc.)
- Page 5 Shock. hand. California Proposition 65 lists chemical Consult the nearest Noritz agent if substances known to the state to cause the water heater location needs to cancer, birth defects, death, serious illness be changed. or other reproductive harm. This product Be sure to do.
- Page 6 4500 ft. above sea level. unit for an extended period of time. Do not drink the first use of hot water from the For installations at higher elevations, contact Noritz unit in the morning. America for Instructions. Do not disassemble the remote controller.
-
Page 7: Table Of Contents
Contents Important Safety Information ............... 2 Contents ......................7 General Parts Main Unit ....................8 Remote Controller ..................9 Initial Operation ................... 10 How to Use Muting the Remote Controller ..............11 Setting and Using the Water Heater ............12 Flow Meter Alarm .................. -
Page 8: General Parts
General Parts Main Unit Outdoor Wall Hanging Model Exhaust Vent Front Cover Air Inlet Water Drain Valve (with Water Filter) (Inside Water Inlet) p.20) Pressure Relief Valve Water Supply Valve Gas Supply Valve * The above illustration shows an example of installation. The exact installation configuration may be slightly different. -
Page 9: Remote Controller
Remote Controller (RC-7649M) What is actually displayed depends on how the water heater is set. Burner On Indicator Setting Buttons When burning, the For setting the hot water temperature, indicator is lit. p.13 and 15) the flow meter alarm, and other settings. Priority Indicator When this indicator is lit, the hot water temperature... -
Page 10: Initial Operation
Initial Operation Before the first use of your water heater, make the following preparations. 1 through 4 Follow steps Open the water supply valve. OPEN CLOSED Open a hot water fixture to confirm that water is available, and then close the fixture again. -
Page 11: How To Use
How to Use Muting the Remote Controller The remote controller will emit a sound when any button is pushed. This sound can be muted if it is desired. * Initial factory setting is with sound Hold the Power On/Off Button for five seconds. Muted Sound No sound... -
Page 12: Setting And Using The Water Heater
How to Use Setting and Using the Water Heater (Starting with the Power Off) Press the Power On/Off Button. The temperature will be displayed on the remote control thermostat. Previous set temperature (Ex.: 110°F) DANGER To prevent scalding: High Temperature Hot Water Heater temperatures over 125°F can cause severe burns instantly or death from scalding. - Page 13 The temperature settings below are examples. The temperature setting °F : necessary depends on the usage, the length of piping and the time of year. The maximum output temperature Contact the installer or Noritz America can be set using the remote when setting the maximum output tem- controller.
-
Page 14: Flow Meter Alarm
How to Use Flow Meter Alarm (Starting with the power off) Set temperature. Press the Power Preparation Always check On/Off Button temperature setting before use. 1. Plug the bath drain. Cold The temperature will be displayed on the remote control thermostat. Check the indicator lights. - Page 15 Water Temperature An alarm will sound for ten seconds when the flow The temperatures settings below are only examples. The °F : temperature setting necessary will depend on the usage, reaches the set level. the length of piping and the time of year. Warm Warmer The water will continue to run unless it is...
-
Page 16: Adjusting The Maximum Output Temperature
How to Use Adjusting the Maximum Output Temperature Change the Turn off the Press and hold the flow temperature using meter alarm set button until power. the setting buttons. a sound is heard (2 sec.). Tone sounds after 2 sec. Down The upper limit of the hot- water supply temperature can... -
Page 17: Preventing Damage From Freezing
* The freeze prevention heaters will not prevent the plumbing external to the unit from freezing. Protect this plumbing with insulation, heat tape or electric heaters, solenoids, or pipe covers. If there remains a freezing risk, contact the nearest Noritz agent. Take the measures below for extremely cold temperatures*. - Page 18 Preventing Damage from Freezing-2 If the water heater will not be used for a long period of time, Drain the water. Drain the water as follows: CAUTION To avoid burns, wait until the equipment cools down before draining the water. The appliance will remain hot after it is turned off.
-
Page 19: Regular Maintenance
Regular Maintenance-1 Periodic Inspection CAUTION To prevent burns or scalding, turn off the power button and wait until the equipment cools before performing maintenance. Be sure to do. For dust and soot in Check For laundry, newspaper, timber, Check the exhaust vent. oil, spray cans and other combustible materials. - Page 20 * The kit includes two full port isolation valves and a pressure relief valve for the hot side. Hot Water Service Valve Contact Noritz for more information. Cold Water Pressure Relief Valve Service Valve Drain Water Intlet...
-
Page 21: Troubleshooting
Troubleshooting-1 Initial Operation • Check for reversed plumbing or crossed pipes. Unit does not attempt to ignite • Check the water drain valve filter. ( p.20 ) when water is running. Unit attempts to ignite but fails • Reset unit and try again. There may be air in the gas line. •... - Page 22 Troubleshooting-2 (Continued) • The unit will not heat the water if the flow rate is less than The water is cold when only a 0.5 gallons per minute. single fixture is open. Open the fixture more or open other fixtures so that a greater flow passes through the unit, and the unit should begin heating again.
- Page 23 Remote Controller • Has there been a power failure? The light on the power button does not come on. • Is the power connected properly? The water temperature changes • The temperature setting and the flow meter alarm setting after a power failure or when the may both need to be reset after a power outage.
- Page 24 Abnormal combustion, Have a professional check the gas supply pressure. low gas supply pressure Contact the nearest Noritz agent. Abnormal combustion Contact the nearest Noritz agent. Contact Noritz America if: • Any other error code appears.
-
Page 25: Follow-Up Service
For repairs after the warranty period, there will be a charge on any service, and service will only be performed if the unit is deemed repairable. Period of Time for Stocking Repair Parts Noritz will stock repair and maintenance parts for this unit within ten (10) years of the date of original installation. Reinstallation If you want to reinstall the appliance at a different location, confirm that the gas and power supply indicated on the rating plate are available at the new location. -
Page 26: Specifications
• Specifications may be changed without prior notice. Specifications • The capacity may differ slightly, depending on the water pressure, water supply, piping conditions, and water temperature. Specifications Item Specification Model Name N-0751M-OD Type Installation Outdoor, Wall Hanging Air Supply/Exhaust Power Vented Ignition Direct Ignition...